0
Correspondence |

Pegging Porous Polyethylene Implants

David R. Jordan, MD, FRCSC
Arch Ophthalmol. 2001;119(9):1393-1395. doi:.
Text Size: A A A
Published online

Extract

I have a number of concerns with a recent ARCHIVES article by Rubin et al.1 I would like to boldasize that their technique is for the flat-surfaced, conical, porous polyethylene-type implant and is based on the observation that "the flattened anterior surface of the conical orbital implant does not move significantly from the intraoperative to the final postoperative position." This technique may not necessarily be successful with a spherical implant. The authors acknowledge that "similar stability may occur with placement of spherical implants, but that would be more difficult to assess clinically." Furthermore, they point out, "with secondary placement of a motility post on spherical surfaces, the desired centration has been difficult to achieve." It is important for the reader to appreciate this distinction. If this technique is applied to a spherical porous polyethylene implant, I suspect that decentration or misdirection of the peg (so that the peg is on an angle) will commonly occur. A peg that is decentrated or ends up on an angle may lead to difficulty creating a good coupling between the peg and posterior surface of the prosthesis, which subsequently leads to poor motility, discomfort, and a possible clicking sound as the peg moves in and out of the couple with the prosthesis.2

Sign In to Access Full Content

Don't have Access?

Register and get free email Table of Contents alerts, saved searches, PowerPoint downloads, CME quizzes, and more

Subscribe for full-text access to content from 1998 forward and a host of useful features

Activate your current subscription (AMA members and current subscribers)

Purchase Online Access to this article for 24 hours

First Page Preview

View Large
First page PDF preview

Figures

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

References

Correspondence

CME
Accreditation Information
The American Medical Association is accredited by the Accreditation Council for Continuing Medical Education to provide continuing medical education for physicians. The AMA designates this journal-based CME activity for a maximum of 1 AMA PRA Category 1 CreditTM per course. Physicians should claim only the credit commensurate with the extent of their participation in the activity. Physicians who complete the CME course and score at least 80% correct on the quiz are eligible for AMA PRA Category 1 CreditTM.
Note: You must get at least of the answers correct to pass this quiz.
You have not filled in all the answers to complete this quiz
The following questions were not answered:
Sorry, you have unsuccessfully completed this CME quiz with a score of
The following questions were not answered correctly:
Commitment to Change (optional):
Indicate what change(s) you will implement in your practice, if any, based on this CME course.
Your quiz results:
The filled radio buttons indicate your responses. The preferred responses are highlighted
For CME Course: A Proposed Model for Initial Assessment and Management of Acute Heart Failure Syndromes
Indicate what changes(s) you will implement in your practice, if any, based on this CME course.
NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s “Cited By” API will populate this tab (http://www.crossref.org/citedby.html).
Submit a Comment

Some tools below are only available to our subscribers or users with an online account.

Sign In to Access Full Content

Related Content

Customize your page view by dragging & repositioning the boxes below.

Articles Related By Topic
Related Topics
PubMed Articles
Jobs