Donahue
SP. Perimetry techniques in neuro-ophthalmology. Curr Opin Ophthalmol. 1999;10420- 428
Trobe
JD, Acosta
PC, Shuster
JJ, Krisher
JP. An evaluation of the accuracy of community based perimetry. Am J Ophthalmol. 1980;90654- 660
American Academy of Ophthalmology,
Automated perimetry. Ophthalmology. 1996;1031144- 1151
Katz
J, Tielsch
JM, Quigley
HA, Sommer
A. Automated perimetry detects visual field loss before manual Goldmann perimetry. Ophthalmology. 1995;10221- 26
McCrary
A, Feigon
J. Computerized perimetry in neuro-ophthalmology. Ophthalmology. 1979;861287- 1301
Trope
GE, Britton
R. A comparison of Goldmann and Humphrey automated perimetry in patients with glaucoma. Br J Ophthalmol. 1987;71489- 493
Johnson
CA, Keltner
JL, Balestrery
F. Suprathreshold static perimetry in glaucoma and other optic nerve disease. Ophthalmology. 1979;861278- 1286
Keltner
JL, Johnson
CA. Automated and manual perimetry, a six-year overview: special emphasis on neuro-ophthalmic problems. Ophthalmology. 1983;9168- 85
Beck
RW, Bergstrom
TJ, Lichter
PR. A clinical comparison of visual field testing with a new automated perimeter, the Humphrey field analyzer, and the Goldmann perimeter. Ophthalmology. 1985;9277- 82
Keltner
JL, Johnson
CA. Short-wavelength automated perimetry in neuro-ophthalmologic disorders. Arch Ophthalmol. 1995;113475- 481
Wong
A, Sharpe
J. A comparison of tangent screen, Goldmann, and Humphrey perimetry in the detection and localization of occipital lesion. Ophthalmology. 2000;107527- 554
Bengtsson
B, Olsson
J, Heijl
A, Rootzen
H. A new generation of algorithms for computerized threshold perimetry: SITA. Acta Ophthalmol Scand. 1997;75368- 375
Bengtsson
B, Heijl
A. Evaluation of a new threshold visual field strategy, SITA, in normal subjects. Acta Ophthalmol Scand. 1998;76165- 169
Bengtsson
B, Heijl
A. Evaluation of a new perimetric threshold strategy, SITA, in patients with manifest and suspect glaucoma. Acta Ophthalmol Scand. 1998;76268- 272
Bengtsson
B, Heijl
A. Comparing significance and magnitude of glaucomatous visual field defects using the SITA and full threshold strategies. Acta Ophthalmol Scand. 1999;77143- 146
Bengtsson
B, Heijl
A. SITA Fast, a new rapid perimetric threshold test: description of methods and evaluation in patients with manifest and suspect glaucoma. Acta Ophthalmol Scand. 1998;76431- 437
Bengtsson
B, Heijl
A. Inter-subject variability and normal limits of the SITA Standard, SITA Fast, and the Humphrey Full Threshold computerized perimetry strategies: SITA STATPAC. Acta Ophthalmol Scand. 1999;77125- 129
Wild
JM, Pacey
IE, Hancock
SA, Cunliff
IA. Between-algorithm, between-individual differences in normal perimetric sensitivity: Full Threshold, FASTPAC, and SITA. Invest Ophthalmol Vis Sci. 1999;401152- 1161
Wild
JM, Pacey
IE, O'Neill
EC, Cunliff
IA. The SITA perimetric threshold algorithms in glaucoma. Invest Ophthalmol Vis Sci. 1999;401998- 2009
Sharma
AK, Goldberg
I, Graham
SL, Mohsin
M. Comparison of the Humphrey Swedish Interactive Thresholding Algorithm(SITA) and full threshold strategies. J Glaucoma. 2000;920- 27
Sulter
G, Steen
C. Use of the Barthel Index and Modified Rankin Scale in acute stroke trials. Stroke. 1999;301538- 1541
Sanabria
O, Feuer
WJ, Anderson
DR. Pseudo-loss of fixation in automated perimetry. Ophthalmology. 1991;9876- 78
Kutzko
KS, Chauhan
BC. Variability in patients with glaucomatous optic nerve damage is reduced using size V stimuli. Invest Ophthalmol Vis Sci. 1992;333162- 3168
Hudson
C, Wild
JM. Assessment of physiologic statokinetic dissociation by automated perimetry. Invest Ophthalmol Vis Sci. 1992;333162- 3168
Safran
AB, Glaser
JS. Statokinetic dissociation in lesions of the anterior visual pathways. Arch Ophthalmol. 1980;98291- 295
Khoury
JM, Donahue
SP, Lavin
PJM.
et al. Comparison of 24-2 and 30-2 perimetry in glaucomatous and non-glaucomatous optic neuropathies. J Neuroophthalmol. 1999;19100- 108