0
Clinicopathologic Reports, Case Reports, and Small Case Series |

Late Posterior Migration of Glass Intraocular Foreign Bodies FREE

Subhransu Ray, MD, PhD; Thomas A. Friberg, MD; Randall R. Beatty, MD; John Loewenstein, MD
[+] Author Affiliations

W. Richard Green, MD
IndividualAuthor

Copyright 2004 American Medical Association. All Rights Reserved.Applicable FARS/DFARS Restrictions Apply to Government Use.

More Author Information
Arch Ophthalmol. 2004;122(6):923-926. doi:10.1001/archopht.122.6.923
Text Size: A A A
Published online
Figures in this Article

The treatment of intraocular foreign bodies (IOFBs) in the previtrectomyera was largely dependent on the source and composition of the material, associatedocular pathologic features, and intraocular location. With modern vitreoretinalsurgical techniques, however, most glass IOFBs are removed despite their inertnature. Occasionally, the surgical complexity involved in their extractionmust be weighed against the risks of leaving them in place. We describe 3patients with retained glass IOFBs in which initially stable or encapsulatedglass IOFBs subsequently migrated and induced further complications or visualsymptoms. There are rare reports of glass IOFBs located initially in the posteriorsegment, migrating anteriorly, and producing additional anterior segment decompensation,such as illustrated in case 3 below. However, cases 1 and 2 are most unusual,as late migration caused additional retinal pathologic conditions.

We followed up 3 patients from 2 institutions with retained glass IOFBsfor more than 6 months. The mechanism of injury, visual acuity, findings fromthe clinical examination, and fundus appearance were documented. Late migrationnecessitated surgical intervention in all 3 patients, although 1 patient refusedsurgery because of special circumstances.

REPORT OF CASES AND RESULTS

Case 1

A 23-year-old man was struck with a glass beer bottle during an altercationand sustained a penetrating open globe injury with multiple glass IOFBs inthe anterior and posterior segments of the left eye (Figure 1). The wound involved 7 mm of the cornea and an additional22 mm on the scleral surface. All anterior segment glass IOFBs were removed(the largest measuring 7 Ă— 6 Ă— 3 mm) and the wound was repaired.One additional fragment with largest dimension measuring approximately 1 cmremained on the inferior equatorial retinal surface. Owing to the risk ofadditional retinal injury with further glass IOFB manipulation, removal wasnot performed at the initial surgery.

Place holder to copy figure label and caption
Figure 1.

Case 1. Preoperative axial computedtomographic scan obtained following initial injury, demonstrating 3 intraocularforeign bodies in the left eye.

Grahic Jump Location

Postoperatively, the glass IOFB became partially encapsulated and remainedimmobile on the inferior retinal surface. Retinal examination 3 months afterinjury revealed an immobile glass IOFB with some overlying gliosis (Figure 2). The patient obtained a visualacuity of 20/50 OS 10 months after the initial injury.

Place holder to copy figure label and caption
Figure 2.

Case 1. Fundus photograph obtained3 months after repair of the open globe injury. A, Posterior pole demonstratespreretinal gliosis with epiretinal membrane formation and macular pucker.B, Inferior peripheral retina shows immobile glass intraocular foreign bodywith overlying early gliosis and underlying chorioretinal scar. The glassintraocular foreign body was immobile with eye movements.

Grahic Jump Location

Twelve months after injury, the patient noted that, "I can see the glassmoving." Visual acuity was 20/60 OS. Ophthalmic examination revealed a mobileglass IOFB with a small underlying retinal laceration, moderate (3+) pigmentcells in the anterior vitreous, and numerous small preretinal opacities (Figure 3). Owing to the mobility of the glassfragment and the potential for further retinal damage, pars plana vitrectomy,pars plana lensectomy, and IOFB removal were performed (Figure 4). Three weeks after surgery, a new round retinal hole wasnoted in the region of the preretinal fibrosis. Argon green laser retinopexywas performed but 1 week later, 4 additional open holes were noted along witha large inferior retinal detachment and early proliferative vitreoretinopathy.The patient underwent pars plana vitrectomy, membrane peeling, further endolasertreatment, 16% perfluoropropane gas tamponade, and scleral buckling. Fiveweeks after this intervention, the patient's retina remained attached, althoughhe had anterior membranes and preretinal fibrosis. The patient was subsequentlylost to follow-up.

Place holder to copy figure label and caption
Figure 3.

Case 1. Fundus photographs taken12 months after repair of the open globe injury. A, Posterior pole view demonstratescontinued epiretinal membrane and pucker but with the new appearance of numeroussmall preretinal opacities. B, Peripheral view shows the glass intraocularforeign body with an underlying retinal laceration.

Grahic Jump Location
Place holder to copy figure label and caption
Figure 4.

Case 1. Intraoperative view obtainedduring pars plana vitrectomy and glass intraocular foreign body removal. A,Glass intraocular foreign body lying over the optic nerve with small piecesof lens cortex on the posterior pole. The glass fragment measured 9 Ă—6 Ă— 3 mm. Standard pars plana vitrectomy techniques were used, and perfluoronliquid was used to mobilize the glass intraocular glass foreign body and protectthe macula. B, The glass intraocular foreign body was then delivered througha limbal wound. Endolaser treatment was applied to the retinal lacerationfollowed by introduction of 16% perfluoropropane gas tamponades.

Grahic Jump Location
Case 2

A 21-year-old man robbing a bank, leaped through a plateglass windowand sustained lacerations to his face and eye. Immediately after capture,ophthalmologic examination revealed a pars plana entry wound; a glass IOFB,estimated to be 4.5 Ă— 1.5 Ă— 1.5 mm, was found lodged on the surfaceof the peripheral retina of his right eye. The glass IOFB was not removedat the initial surgery because of poor posterior visualization and the riskof retinal injury during the glass IOFB manipulation. The anterior segmentwas not damaged. Other than vitreous hemorrhage, no additional pathologiccondition was found. The patient's visual acuity eventually returned to 20/20OD. Fundus examination of the peripheral retina revealed a large immobileglass IOFB with localized fibrosis around its base, where it was in appositionto the retina. The patient was sentenced to life in prison for the robberyand the killing of a guard, but was examined periodically in prison and theglass IOFB remained in place in its peripheral location. As no inflammationdeveloped and because the right eye was quiet and stable with 20/20 visualacuity, subsequent removal of the glass IOFB was not felt to be necessary.

On awakening in his cell 6 years after the crime, he noted double visionand beautiful "rainbows" in his right eye when he lay supine in his cell.He was examined in the prison and the glass IOFB had dislodged from its originallocation and was now resting on the fovea when the patient was in the supineposition (Figure 5). When sitting,the glass IOFB drifted inferiorly away from the macula and symptoms cleared.

Place holder to copy figure label and caption
Figure 5.

Case 2. Six years after the initialinjury, the glass intraocular foreign body migrated posteriorly over the maculaand caused symptoms of positional visual obscuration.

Grahic Jump Location

Surgical removal of the glass IOFB through a pars plana vitrectomy wasrecommended and the risks of surgery were discussed. The inmate, however,insisted that if there were any complications whatsoever, he would see toit that his surgeon was killed. Further periodic follow-up was, therefore,offered under these unusual circumstances. The patient was seen again 6 monthslater with no change in his eye findings, but he was ultimately transferredto another high-security facility and was lost to follow-up.

Case 3

A 21-year-old man who was a passenger involved in a motor vehicle collisionsustained a head injury with a severe scalp laceration and an open left globe.A glass IOFB lacerated the cornea and produced a cataract, necessitating cataractremoval and corneal wound repair. The vitreous was not removed, as the corneawas cloudy during the wound repair. Visual acuity 1 week after the procedurewas 20/400 OS from corneal edema. The fellow right eye was normal with uncorrected20/25 visual acuity.

On funduscopic examination, the retina was not injured, but a 4 Ă—4 Ă— 3-mm rectangular piece of glass was present in the inferior vitreousjust posterior to the equator, as shown on computed tomography (Figure 6). It did not move with positioning and, after discussion,he decided to be examined periodically for possible fragment migration.

Place holder to copy figure label and caption
Figure 6.

Case 3. Preoperative computedtomographic scan of patient demonstrating glass intraocular foreign body inposterior chamber.

Grahic Jump Location

Visual acuity remained 20/400 OS, and the patient's condition was monitoredat monthly intervals for 6 months. However, almost 7 months after the injury,he was seen in the emergency department reporting pain and discomfort in theleft eye. The glass IOFB had migrated through the pupil into the anteriorchamber and was lodged inferiorly causing local corneal edema. Removal ofthe glass IOFB was performed through a keratotomy incision. The retina remainedunaffected, except for some localized fibrosis at the former site of the glassIOFB. A few weeks thereafter, the cornea was clear, and visual acuity witha contact lens improved to 20/25 OS.

Glass IOFBs can pose special challenges. They are often large relativeto the entry wound, and surgical removal can be challenging, particularlyif they are of a large cuboidal or irregular shape. Grasping the glass fragmentwith foreign body forceps is often difficult and sharp edges can cause retinalor lenticular injury during extrication. In some cases, the level of surgicalcomplexity required for extraction combined with their inert nature may dictatethat a glass IOFB be retained in the posterior segment.

One of the largest series of glass IOFBs is provided by Gopal et al,1 in which they report on 51 eyes with glass IOFBs.In 8 eyes, glass pieces were left behind without any untoward events at anaverage of 31 months' follow-up. In none of these eyes was any late anterioror posterior segment complication encountered. The authors hypothesized thatpreretinal fibrosis encapsulates the glass IOFB and provides additional security.In this same study, Gopal et al encountered iatrogenic retinal breaks in 13eyes when attempts were made to remove the glass IOFB.

A review of the literature by Milkowski2 revealsnumerous cases of retained glass IOFBs near the optic nerve, retina, vitreous,and lens where complications did not develop. This article also summarizesrare cases of migration of posterior IOFBs into the anterior chamber causingcataract, corneal edema, and iridocyclitis.2 A1991 report by Saar et al3 describes theanterior migration of glass splinters from the vitreous to the anterior chambercausing corneal edema. They also stated in this article that the "migrationof intraocular glass is always from back forwards."3 (p189) A similar case with anterior migration is presented herein ascase 3. However, late posterior segment migration as in cases 1 and 2, causingadditional retinal pathologic conditions or symptoms must be rare and, toour knowledge, have not been previously reported.

We describe 3 eyes with glass IOFBs that migrated after they were deemedstable with partial encapsulation or entrapment in the vitreous base. In 2cases, partially encapsulated glass IOFBs caused late posterior segment findingsincluding retinal laceration and obstruction of macular vision. Though thelate posterior migration of retained glass IOFB is considered rare, thesecases highlight the need for close follow-up in such cases. Early interventionwith glass IOFB removal must be weighed against the hazards of removal andthe necessity of close follow-up.

The authors have no relevant financial interest in this article.

This study was supported in part by funding from the American OphthalmologicalSociety–Herman Knapp Foundation, Cleveland, Ohio (Dr Ray).

We acknowledge the invaluable assistance of Magdalena Krzystolik, MD,in the preparation of the manuscript.

Corresponding author: John Loewenstein, MD, Retina Service, MassachusettsEye and Ear Infirmary, Department of Ophthalmology, Harvard Medical School,243 Charles St, Boston, MA 02114 (e-mail: john_loewenstein@meei.harvard.edu).

Gopal  L, Banker  A, Deb  N.  et al.  Management of glass intraocular foreign bodies. Retina. 1998;18213- 220
PubMed
Milkowski  S. A rare case of spontaneous shifting of intraocular glass foreign body21 years after injury [in Polish]. Wiad Lek. 1978;311065- 1069
PubMed
Saar  I, Raniel  J, Neumann  E. Recurrent corneal oedema following late migration of intraocular glass. Br J Ophthalmol. 1991;75188- 189
PubMed

First Page Preview

First page PDF preview

Figures

Place holder to copy figure label and caption
Figure 6.

Case 3. Preoperative computedtomographic scan of patient demonstrating glass intraocular foreign body inposterior chamber.

Grahic Jump Location
Place holder to copy figure label and caption
Figure 5.

Case 2. Six years after the initialinjury, the glass intraocular foreign body migrated posteriorly over the maculaand caused symptoms of positional visual obscuration.

Grahic Jump Location
Place holder to copy figure label and caption
Figure 4.

Case 1. Intraoperative view obtainedduring pars plana vitrectomy and glass intraocular foreign body removal. A,Glass intraocular foreign body lying over the optic nerve with small piecesof lens cortex on the posterior pole. The glass fragment measured 9 Ă—6 Ă— 3 mm. Standard pars plana vitrectomy techniques were used, and perfluoronliquid was used to mobilize the glass intraocular glass foreign body and protectthe macula. B, The glass intraocular foreign body was then delivered througha limbal wound. Endolaser treatment was applied to the retinal lacerationfollowed by introduction of 16% perfluoropropane gas tamponades.

Grahic Jump Location
Place holder to copy figure label and caption
Figure 3.

Case 1. Fundus photographs taken12 months after repair of the open globe injury. A, Posterior pole view demonstratescontinued epiretinal membrane and pucker but with the new appearance of numeroussmall preretinal opacities. B, Peripheral view shows the glass intraocularforeign body with an underlying retinal laceration.

Grahic Jump Location
Place holder to copy figure label and caption
Figure 2.

Case 1. Fundus photograph obtained3 months after repair of the open globe injury. A, Posterior pole demonstratespreretinal gliosis with epiretinal membrane formation and macular pucker.B, Inferior peripheral retina shows immobile glass intraocular foreign bodywith overlying early gliosis and underlying chorioretinal scar. The glassintraocular foreign body was immobile with eye movements.

Grahic Jump Location
Place holder to copy figure label and caption
Figure 1.

Case 1. Preoperative axial computedtomographic scan obtained following initial injury, demonstrating 3 intraocularforeign bodies in the left eye.

Grahic Jump Location

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

Gopal  L, Banker  A, Deb  N.  et al.  Management of glass intraocular foreign bodies. Retina. 1998;18213- 220
PubMed
Milkowski  S. A rare case of spontaneous shifting of intraocular glass foreign body21 years after injury [in Polish]. Wiad Lek. 1978;311065- 1069
PubMed
Saar  I, Raniel  J, Neumann  E. Recurrent corneal oedema following late migration of intraocular glass. Br J Ophthalmol. 1991;75188- 189
PubMed

Correspondence

CME Course for:


You need to register in order to view this quiz.


To understand the clinical management of acute heart failure syndromes.
Accreditation Information The American Medical Association is accredited by the Accreditation Council for Continuing Medical Education to provide continuing medical education for physicians.
The AMA designates this journal-based CME activity for a maximum of 1 AMA PRA Category 1 CreditTM per course. Physicians should claim only the credit commensurate with the extent of their participation in the activity.
Physicians who complete the CME course and score at least 80% correct on the quiz are eligible for AMA PRA Category 1 CreditTM.
Note: You must get at least of the answers correct to pass this quiz.
Note: You must get at least of the answers correct to pass this quiz.
You have not filled in all the answers to complete this quiz
The following questions were not answered:
Sorry, you have unsuccessfully completed this CME quiz with a score of
The following questions were not answered correctly:
For CME Course: A Proposed Model for Initial Assessment and Management of Acute Heart Failure Syndromes
Indicate what changes(s) you will implement in your practice, if any, based on this CME course.
To view and print your certificate and access a summary of your CME courses go to My CME.
NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s “Cited By” API will populate this tab (http://www.crossref.org/citedby.html).
Submit a Comment

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Articles Related By Topic
Related Topics