0
Clinicopathologic Reports, Case Reports, and Small Case Series |

Descemet Stripping With Endothelial Keratoplasty in Aphakic Eyes FREE

Leejee H. Suh, MD; George D. Kymionis, MD, PhD; William W. Culbertson, MD; Terrence P. O’Brien, MD; Sonia H. Yoo, MD
[+] Author Affiliations

W. Richard Green, MD
IndividualAuthor

Copyright 2008 American Medical Association. All Rights Reserved. Applicable FARS/DFARS Restrictions Apply to Government Use.

More Author Information
Arch Ophthalmol. 2008;126(2):268-270. doi:10.1001/archophthalmol.2007.32
Text Size: A A A
Published online
Figures in this Article

Descemet stripping with endothelial keratoplasty (DSEK) has gained popularity for the treatment of endothelial disorders.1 4 In this technique, the Descemet membrane and endothelium are stripped, and a donor posterior lamellar disc is inserted and allowed to unfold flush to the bare stromal surface.1 4 A crucial step to promote disc attachment is filling of the anterior chamber with air to push the donor tissue up against the recipient cornea.3 In aphakic patients, maintenance of air in the anterior chamber is a challenge. In this small case series, we provide the results of DSEK in 3 aphakic patients.

All the patients were part of a prospective clinical study of the safety and efficacy of DSEK in patients with endothelial diseases. Informed consent was obtained in accordance with the institutional review board of Bascom Palmer Eye Institute (Miami, Florida) and the Declaration of Helsinki.

Case 1

A 75-year-old man was first seen with a history of aphakic bullous keratopathy in his left eye. He had undergone extracapsular cataract extraction in 1973. In his left eye, the best-corrected visual acuity was counting fingers, and the intraocular pressure (IOP) was 18 mm Hg. At the end of uneventful DSEK, the anterior chamber was completely filled with filtered air. The patient was left face up for 1 hour, and afterward 50% of the air was evacuated. One drop of 1% cyclopentolate was instilled to prevent pupillary block. On the first postoperative day, the disc was attached, 40% air was present, and the IOP was 16 mm Hg. Blood was present at the interface peripherally (Figure 1A). Anterior chamber optical coherence tomography (Visante; Carl Zeiss Meditec, Dublin, California) revealed a well-apposed corneal disc with increased signal peripherally, secondary to the interface blood (Figure 1B and C). Corneal edema progressively resolved, and at postoperative month 1 the visual acuity was 20/100.

Place holder to copy figure label and caption
Figure 1.

Case 1. A, Slitlamp photograph shows successful button apposition 1 week after Descemet stripping with endothelial keratoplasty (DSEK). Arrows indicate blood at the interface that is not in the visual axis. B, Optical coherence tomograph of the cornea after DSEK. Note the meniscus-shaped DSEK button. Arrow indicates the area of increased signal intensity, probably representing interface blood. C, Closer view of the optical coherence tomograph of the cornea after DSEK. Note that the button is well apposed. Arrow indicates the area of interface blood.

Grahic Jump Location
Case 2

An 85-year-old woman was first seen with a history of pseudophakic bullous keratopathy in her left eye. She had undergone cataract surgery with scleral fixation of an intraocular lens (IOL) in 1992. In the left eye, the best-corrected visual acuity was hand motions, and the IOP was 21 mm Hg. Posterior pole ultrasonographic findings were normal. Intraoperatively, the IOL dislocated posteriorly, and a pars plana vitrectomy with lens retrieval was performed through an enlarged scleral tunnel incision. Retinal examination revealed an attached retina. She was left aphakic. The donor corneal disc was attached under an anterior chamber full of air. One drop of 1% cyclopentolate was applied, the patient was left face up for 1 hour, and 70% air was left. On the first postoperative day, the air bubble and the corneal disc were absent. Ultrasonographic results showed the donor corneal disc in the inferior anterior retina (Figure 2). After penetrating keratoplasty, a total retinal detachment developed, and she had no light perception.

Place holder to copy figure label and caption
Figure 2.

Orbital ultrasound after Descemet stripping with endothelial keratoplasty in case 2 shows a membranelike echogenic material (arrow) adherent to the fundus near the equator, measuring 0.2 mm deep and 4.0 mm wide, and mild vitreous opacities.

Grahic Jump Location
Case 3

A 58-year-old man was first seen with a history of recurrent retinal detachments in his right eye due to high myopia. He had undergone extracapsular cataract extraction, vitrectomy, and silicone oil placement in the 1980s. In his right eye, the best-corrected visual acuity was 20/100. Examination revealed bullous keratopathy with silicone oil in the anterior chamber and vitreous and a large iridectomy inferiorly (Figure 3A), and the IOP was 12 mm Hg. Fundus examination revealed a normal optic nerve with an attached retina. The patient underwent DSEK with silicone oil removal. Intraoperatively, the air bubble could not be maintained in the anterior chamber, and sulfur hexafluoride (SF6) was injected into the anterior chamber to 100% fill and was later evacuated to 70% fill. The gas bubble remained, with good apposition of the donor corneal disc postoperatively. In the first postoperative month, his best-corrected visual acuity was 20/40, and the cornea was clear (Figure 3A). Subsequently, recurrent retinal detachments developed, but the donor corneal disc remained attached with corneal deturgescence (Figure 3B and C).

Place holder to copy figure label and caption
Figure 3.

Slitlamp photograph of case 3 at postoperative month 1 shows a clear cornea (A), and on anterior segment optical coherence tomography (B and C [magnified view]), there is good apposition of the button. Note the large peripheral iridectomy inferiorly.

Grahic Jump Location

Descemet stripping with endothelial keratoplasty preserves the cornea's biomechanical properties and may result in more rapid visual recovery than penetrating keratoplasty.2 The safety and efficacy of DSEK in aphakic eyes still needs to be determined. Introduction of air into the anterior chamber promotes attachment of the donor corneal disc to the recipient cornea.3 Maintenance of air is difficult in aphakic eyes in which there is no capsular bag to isolate the anterior chamber.

Price and Price3 described 2 eyes with aphakic bullous keratopathy before DSEK. A secondary IOL was implanted with DSEK in one eye, and a secondary IOL was implanted 4 months after DSEK in the other eye. A disc detachment found in one eye was successfully repositioned. In the present study, we described 3 aphakic patients who underwent DSEK with varied results. In the first patient, air was maintained postoperatively, and a favorable outcome was found. In the second patient, a serious complication occurred in which the donor disc displaced posteriorly. The intraoperative enlargement of the incision may have allowed a potential route for air to escape from the anterior chamber. In the third patient, owing to the large iridectomy, the air bubble disappeared behind the pupil. A longer-lasting gas (SF6) with higher buoyancy than air was used to fill the anterior chamber, and good apposition of the donor disc was found postoperatively.

The main event leading to a favorable outcome in these cases may be the ability to maintain air in the anterior chamber in the first postoperative hours in addition to strict face-up positioning. The use of long-lasting, higher-buoyancy gases could be a possible solution for these patients. Ellis and Cohen5 showed the use of SF6for the treatment of Descemet membrane detachments after cataract surgery. Recently, some researchers6 have suggested using a suture to pull the disc into the eye and secure the disc to the recipient cornea. This technique may be of particular use in aphakic eyes, in which maintenance of an air bubble is more difficult.

In conclusion, owing to the small sample size and the retrospective nature of the study, we cannot conclude a lower rate of success of DSEK in aphakic patients. The possibility of a lower success rate of DSEK in aphakic eyes compared with pseudophakic or phakic eyes is an issue that needs further study. The potential for posterior dislocation of the donor corneal disc in aphakic eyes must be taken into consideration. Longer-lasting, higher-buoyancy gases (such as SF6) could be used as alternatives to air, but the possible toxic effect to endothelial cells should be elucidated.

Correspondence:Dr Yoo, Cornea and External Diseases, Bascom Palmer Eye Institute, 900 NW 17th St, Miami, FL 33136 (syoo@med.miami.edu).

Financial Disclosure:None reported.

Melles  GRJ, Wijdh  RHJ, Nieuwendaal  CP. A technique to excise the Descemet membrane from a recipient cornea (descemetorhexis). Cornea 2004;23 (3) 286- 288
PubMed
Price  FW, Price  MO. Descemet's stripping with endothelial keratoplasty in 50 eyes: a refractive neutral corneal transplant. J Refract Surg 2005;21 (4) 339- 345
PubMed
Price  FW, Price  MO. Descemet's stripping with endothelial keratoplasty in 200 eyes: early challenges and techniques to enhance donor adherence. J Cataract Refract Surg 2006;32 (3) 411- 418
PubMed
Culbertson  WW. Descemet stripping endothelial keratoplasy. Int Ophthalmol Clin 2006;46 (3) 155- 168
PubMed
Ellis  DR, Cohen  KL. Sulfur hexafluoride gas in the repair of Descemet's membrane detachment. Cornea 1995;14 (4) 436- 437
PubMed
Sorenson  A. DSEK prolene pull. http://www.newmediamedicine.com/videos/2007/01/17/dsek-prolene-pull-andrew-sorenson-md/. Accessed March 18, 2007

First Page Preview

First page PDF preview

Figures

Place holder to copy figure label and caption
Figure 1.

Case 1. A, Slitlamp photograph shows successful button apposition 1 week after Descemet stripping with endothelial keratoplasty (DSEK). Arrows indicate blood at the interface that is not in the visual axis. B, Optical coherence tomograph of the cornea after DSEK. Note the meniscus-shaped DSEK button. Arrow indicates the area of increased signal intensity, probably representing interface blood. C, Closer view of the optical coherence tomograph of the cornea after DSEK. Note that the button is well apposed. Arrow indicates the area of interface blood.

Grahic Jump Location
Place holder to copy figure label and caption
Figure 2.

Orbital ultrasound after Descemet stripping with endothelial keratoplasty in case 2 shows a membranelike echogenic material (arrow) adherent to the fundus near the equator, measuring 0.2 mm deep and 4.0 mm wide, and mild vitreous opacities.

Grahic Jump Location
Place holder to copy figure label and caption
Figure 3.

Slitlamp photograph of case 3 at postoperative month 1 shows a clear cornea (A), and on anterior segment optical coherence tomography (B and C [magnified view]), there is good apposition of the button. Note the large peripheral iridectomy inferiorly.

Grahic Jump Location

Tables

Interactive Graphics

Video

Country-Specific Mortality and Growth Failure in Infancy and Yound Children and Association With Material Stature

Use interactive graphics and maps to view and sort country-specific infant and early dhildhood mortality and growth failure data and their association with maternal

Melles  GRJ, Wijdh  RHJ, Nieuwendaal  CP. A technique to excise the Descemet membrane from a recipient cornea (descemetorhexis). Cornea 2004;23 (3) 286- 288
PubMed
Price  FW, Price  MO. Descemet's stripping with endothelial keratoplasty in 50 eyes: a refractive neutral corneal transplant. J Refract Surg 2005;21 (4) 339- 345
PubMed
Price  FW, Price  MO. Descemet's stripping with endothelial keratoplasty in 200 eyes: early challenges and techniques to enhance donor adherence. J Cataract Refract Surg 2006;32 (3) 411- 418
PubMed
Culbertson  WW. Descemet stripping endothelial keratoplasy. Int Ophthalmol Clin 2006;46 (3) 155- 168
PubMed
Ellis  DR, Cohen  KL. Sulfur hexafluoride gas in the repair of Descemet's membrane detachment. Cornea 1995;14 (4) 436- 437
PubMed
Sorenson  A. DSEK prolene pull. http://www.newmediamedicine.com/videos/2007/01/17/dsek-prolene-pull-andrew-sorenson-md/. Accessed March 18, 2007

Correspondence

CME Course for:


You need to register in order to view this quiz.


To understand the clinical management of acute heart failure syndromes.
Accreditation Information The American Medical Association is accredited by the Accreditation Council for Continuing Medical Education to provide continuing medical education for physicians.
The AMA designates this journal-based CME activity for a maximum of 1 AMA PRA Category 1 CreditTM per course. Physicians should claim only the credit commensurate with the extent of their participation in the activity.
Physicians who complete the CME course and score at least 80% correct on the quiz are eligible for AMA PRA Category 1 CreditTM.
Note: You must get at least of the answers correct to pass this quiz.
Note: You must get at least of the answers correct to pass this quiz.
You have not filled in all the answers to complete this quiz
The following questions were not answered:
Sorry, you have unsuccessfully completed this CME quiz with a score of
The following questions were not answered correctly:
For CME Course: A Proposed Model for Initial Assessment and Management of Acute Heart Failure Syndromes
Indicate what changes(s) you will implement in your practice, if any, based on this CME course.
To view and print your certificate and access a summary of your CME courses go to My CME.
NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s “Cited By” API will populate this tab (http://www.crossref.org/citedby.html).
Submit a Response

Some tools below are only available to our subscribers or users with an online account.

Web of Science® Times Cited: 7

Related Content

Customize your page view by dragging & repositioning the boxes below.

Articles Related By Topic
Related Topics
PubMed Articles
Targeted corneal transplantation.
Curr Opin Ophthalmol. Published online May 5, 2012.